Complaint hotline for free consultation
13074271912

Problems and Prevention Measures in the Construction Process of Aluminum Honeycomb Panel | FAQ | Kaimai Metal Building Materials News

China's earliest production and processing of aluminum veneer ceiling, one of the curtain wall manufacturers

Problems and Prevention Measures in the Construction Process of Aluminum Honeycomb Panel

文章出处:广州Problems and Prevention Measures in the Construction Process of Aluminum Honeycomb Panel | FAQ | Kaimai Metal Building Materials有限公司 人气:-Published: 2016-01-14 10:17:00

aluminum honeycomb panel制造技术源自航空业,作为幕墙系统的装饰面板不仅经久耐用、板面超大,而且具有极好的平整度。建筑幕墙装饰用aluminum honeycomb panel一般选用15mm20mm25mmThe aluminum honeycomb panel has the advantages of excellent material selection, advanced technology and reasonable structure. It not only has excellent performance in large scale and flatness, but also has many choices in shape, surface treatment, color, installation system and so on.

The installation of aluminum honeycomb panel involves many types of work, the process is complex, the construction is difficult, and quality problems are more likely to occur. Usually manifested in the following aspects:

1.The aluminum honeycomb panel surface is uneven and the joints are uneven.

Cause

(1) The connecting code is not firmly fixed, resulting in offset.

(2) The code piece is not installed straight.

(3) The aluminum honeycomb panel surface itself is uneven.

Prevention and control measures: to ensure the fixing of the connecting piece, the line should be placed and positioned when the code piece is fixed, and the quality of the aluminum honeycomb panel should be strictly checked before the plate is placed, and the product number provided by the supplier should be checked.

2.Sealant cracking, resulting in gas penetration or rain leakage.

Cause:

(1) The injection part is not clean.

(2) The glue seam depth is too large, resulting in three-sided bonding.

(3) The glue is contaminated or damaged by dust before it is completely bonded.

(4) The flatness error of keel and accessories is too large, and the gap between plates is not correctly reserved.

Prevention and control measures:

(1) Adequate cleaning of gaps between plates(Especially the bonding surface)and dried.

(2) Filling PVC foaming material in deep glue joint(small round bar), so that the glue to form a two-sided bond, to ensure the depth of the joint.

(3) Check whether the position of the bottom groove of the cover plate is correct, and adjust the distance between the aluminum honeycomb panels on both sides of the cover strip.

(4) Careful curing after injection until its safe hardening.

3.The position of embedded parts is inaccurate, which makes it difficult for horizontal and vertical materials to be fixedly connected with them.

Cause:

(1) When embedded parts are placed, they deviate from the installation reference line.

(2) The embedded parts are not firmly connected with formwork and reinforcement, so that their positions change during concrete pouring.

Prevention and control measures:

(1) Before placing the embedded parts, carefully check their installation baseline and determine their accurate position.

(2) Adopt appropriate methods to firmly connect the embedded part formwork and reinforcement(Such as binding, welding, etc.)

Remedial measures: if there is a large embedded deviation or individual leakage after the completion of the structure construction, it is necessary to remedy it in time. Its method is:

(1) If the recessed surface of the embedded part exceeds the allowable deviation range, the extended iron code shall be used for remedy.

(2) If the embedded parts protrude outward beyond the allowable deviation range, shorten the iron code or remove the original embedded parts, and use expansion bolts to fasten the iron code on the concrete structure.

(3) If the upward or downward deviation of the embedded part exceeds the deviation range, modify the connection hole of the mullion or adjust the connection position with expansion bolt.

(4) If the embedded parts are leaked, they shall be connected by expansion bolts or re-buried after the concrete is removed.

The above repair methods shall be approved by the design department.

Recommended article:

Research and Development of New Hanging Technology for Aluminum Honeycomb Panel

/Article/xinxinglvfengwobangu_1.html

Effect of Adhesive on Aluminum Honeycomb Panel

/Article/jiaozhanjiduilvfengw_1.html

What are the advantages of using aluminum honeycomb panels?

/Article/shiyonglvfengwobandu_1.html

 


Keyword of this article:fireproof aluminum composite panel, double sided aluminum composite panel